McKesson # 552343 951314 1127861 472929 805502
Description 其他传染病Infectiou检测组件状态s Mononucleosis 30 Tests CLIA Waived Sample Dependent Other Infectious Disease Test Kit McKesson Consult™ Infectious Mononucleosis 25 Tests CLIA Waived Sample Dependent Other Infectious Disease Test Kit QuickVue® Acute Conjunctivitis (Pink Eye) 10 Tests CLIA Waived Other Infectious Disease Test Kit OSOM® Mono Test Infectious Mononucleosis 25 Tests CLIA Waived Sample Dependent Other Infectious Disease Test Kit OraQuick® HCV Hepatitis C Test 25 Tests CLIA Waived
Manufacturer # 84M30 5012 20324 145 1001-0181
Brand Status McKesson Consult™ QuickVue® OSOM® Mono Test OraQuick® HCV
Manufacturer LifeSign McKesson Brand Quidel Sekisui Diagnostics Orasure Technologies
Invoice TEST KIT, MONO STATUS W/CNTRL MODERATE (30/BX) TEST KIT, MONO WAIVED APPRV F/ALL AGES (25/KT) TEST KIT, CONJUNCTIVITIS ADENOVIRAL QUICKVUE (10 TEST/KT) TEST KIT, MONO OSOM WAIVED (25/KT 6KT/CS) GENZME ANTIBODY TEST, ORAQUICK HCV RAPID (25/KT)
Log In to Order Log In to Order Log In to Order Log In to Order Log In to Order

Comparison

CLIA Classification CLIA Waived for Whole Blood / CLIA Moderate Complexity for Serum, Plasma CLIA Waived for Whole Blood / CLIA Moderately Complex for Serum, Plasma CLIA Waived CLIA Waived for Whole Blood / CLIA Moderate Complexity for Serum, Plasma CLIA Waived
CLIA Classified CLIA Waived Sample Dependent CLIA Waived Sample Dependent CLIA Waived CLIA Waived Sample Dependent CLIA Waived
Contents 1 (30) Test Devices, Positive Control, Negative Control, Developer Solution, Package Insert, Procedure Card, (30) Sample Transfer Pipettes for use with Serum / Plasma, (30) Sample Transfer Pipettes for use with Whole Blood (25) Cassettes in Sealed Pouches, (25) 10 µL Black Line Sample Transfer Pipettes for use with Serum / Plasma, (25) 25 µL Red Line Sample Transfer Pipettes for use with Whole Blood, 6 mL Developer Solution, 0.5 mL Negative Control, 0.5 mL Positive Control, Instructional insert, Procedure card (10) Individually Packaged Sample Collector, (10) Individually Packaged Test Cassette, (10) Buffer Vial, Package Insert (25) Test Sticks in Container, (25) Test Tubes, (25) Transfer Pipettes, Diluent, Mono Positive Control, Mono Negative Control, Workstation, Directional Insert
  • Single Use Test Devices
  • Buffered Developer Solution Vials
  • Test Stands
  • Specimen Collection Loops
  • Package Insert
Latex Free Indicator Not Made with Natural Rubber Latex
Number of Tests 30 Tests 25 Tests 10 Tests 25 Tests 25 Tests
Product Dating McKesson Acceptable Dating: we will ship >= 30 days McKesson Acceptable Dating: we will ship >= 90 days McKesson Acceptable Dating: we will ship >= 90 days McKesson Acceptable Dating: we will ship >= 90 days McKesson Acceptable Dating: we will ship >= 180 days
Sample Type Whole Blood / Serum / Plasma Sample Whole Blood / Serum / Plasma Sample Tear Sample Whole Blood / Serum / Plasma Sample Whole Blood Sample
Technology Direct Sampling Micro-Filtration Technology Immunochromatographic Dipstick Technology
Test Format Test Strip Format Cassette Format Cassette Format Test Strip Format Test Device Format
Test Method Lateral Flow Method Chromatographic Immunoassay Lateral Flow Method
Test Name Infectious Mononucleosis Infectious Mononucleosis Acute Conjunctivitis (Pink Eye) Infectious Mononucleosis Hepatitis C Test
Test Type Infectious Disease Immunoassay Infectious Disease Immunoassay Infectious Disease Immunoassay Infectious Disease Immunoassay Antibody Test
Time to Results 3 to 8 Minute Results 8 Minute Results 10 Minute Results 5 Minute Results 20 Minute Results
UNSPSC Code 41116126 41116126 41116144 41116126 41116126
Application Other Infectious Disease Test Kit Other Infectious Disease Test Kit Other Infectious Disease Test Kit Other Infectious Disease Test Kit Other Infectious Disease Test Kit
Country of Origin United States United States United States United States United States
Purchase Program Type Standard Purchase Standard Purchase Standard Purchase Standard Purchase Standard Purchase
Reading Type Visual Read Visual Read Visual Read Visual Read Visual Read
Specialty Immunoassay Immunoassay Immunoassay Immunoassay Immunoassay
Test Kit Type Rapid Rapid Rapid Rapid Rapid
Features and Benefits
  • Single reagent procedure provides positive results in 8 minutes
  • Fingerstick whole blood capability facilitates easy screening
  • Walkaway procedure accommodates interruptions in workflow
  • Superior 99.9% sensitivity
  • Specificity 98.8%
  • McKesson Consult™ Mononucleosis Cassette Test
  • A rapid test for the qualitative detection of Infectious Mononucleosis (IM) heterophile antibodies in whole blood, serum and plasma.
  • CLIA Waived for Whole Blood / CLIA Moderately Complex for Serum or Plasma.
  • Contents: 25 Cassettes (in sealed pouches), 25 (10 µL) (black line) Sample transfer pipettes for use with serum/plasma, 25 (25 µL) (red line) Sample transfer pipettes for use with whole blood, Developer solution (6 mL; Phosphate saline buffer containing 0.1% Sodium Azide as a preservative), Negative control (0.5 mL; diluted human serum containing 0.1% Sodium Azide as a preservative), Positive control (0.5 mL; diluted human serum containing IM Heterophile Antibodies and 0.1% Sodium Azide as a preservative), Instructional insert, Procedure card
  • Results in as fast as eight minutes.
  • Greater than 99% accuracy.
  • External positive and negative quality controls provided.
  • Acute infection determination (IgM Specific Conjugate).
  • For in vitro diagnostic use only.
  • 18-month shelf life.
  • Not made with natural rubber latex.
  • Packaged: 25 Tests Per Box
  • QuickVue Adenoviral conjunctivitis Test is a CLIA-waived test for the visual, qualitative in vitro detection of Adenoviral antigens (hexon protein) directly from eye fluid
  • Identify, isolate and manage contagious patients, preventing spread to other patients and staff
  • Offers an accurate, fast, disposable platform that is easy to use
  • 90% sensitivity and 96% specificity
  • Disposable test
  • No additional equipment is needed to administer or interpret
  • 99% sensitivity; 96% specificity
  • Results in 5 minutes
  • 99% sensitivity; 96% specificity
  • Kit includes positive and negative controls
  • The OraQuick® HCV test is FDA approved for detecting HCV antibodies in fingerstick and venipuncture whole blood
  • Our simple platform enables healthcare providers to deliver an accurate diagnosis in 20 minutes
  • The OraQuick HCV Rapid Antibody Test is comprised of both a single-use test device and vial containing a pre-measured amount of a buffered developer solution
  • The test consists of a sealed pouch with two separate compartments for each component
  • The developer solution facilitates the capillary flow of the specimen into the device and onto the assay strip
  • Kit includes: 25 divided pouches each containing a test device, absorbent packet, and developer solution vial (each contains 0.75 mL of a buffered saline solution with an antimicrobial agent); 5 reusable test stands; 25 specimen collection loops; package insert