- #847786
- Siemens #10453531
Refurbished Immunoassay Analyzer Stratus® CS Acute Care™ CLIA Non-Waived
ANALYZER, CARDIAC STRATUS REFURB SEMDIA
Features
- Easy-to-use and ideal for all skill levels
- Full cardiac menu including guideline acceptable troponin I and D-dimer (with pulmonary embolism exclusion) assays
- Use in the acute care setting to decrease turnaround time, patient length of stay and total patient costs
- More …
Product Details Email
Product Specifications
McKesson # | 847786 |
Manufacturer # | 10453531 |
Brand | Stratus® CS Acute Care™ |
Manufacturer | Siemens |
Country of Origin | United States |
Analyzer Type | Benchtop |
Application | Refurbished Immunoassay Analyzer |
CLIA Classified | CLIA Non-Waived |
Dimensions | 18 X 22 X 27 Inch |
Power Source | 103 to 127 VAC/207 to 253 VAC, 47/63 Hz, 0.7 to 1.4 A, 400 W |
Purchase Program Type | Refurbished |
Readout Type | Digital, Printer |
Sample Capacity | 3 mL |
Sample Type | Whole Blood / Plasma Sample |
Test Name | Troponin-I, Myoglobin, CK-MB, ßhCG, D-Dimer, NT-ProBNP, CardioPhase hsCRP |
Throughput | 4 Tests / 26 Minutes |
Time to Results | 14 Minute Results |
UNSPSC Code | 41115819 |
User Interface | Barcode Reader |
Weight | 150 lbs. |
Features
- Easy-to-use and ideal for all skill levels
- Full cardiac menu including guideline acceptable troponin I and D-dimer (with pulmonary embolism exclusion) assays
- Use in the acute care setting to decrease turnaround time, patient length of stay and total patient costs
- Rapid turnaround time: 14 minutes to first result, and 4 minutes for each subsequent result
- A broad menu of tests to support better chest pain differentiation from a single sample, on a single run, on a single instrument
- Simple operation for all skill levels: Load sample, rotor, TestPak™ cartridge(s) and press Start
- System accepts blood directly from collection tube-no sample preparation, no manual dilutions
- Barcode readers and lockout features for near-patient testing compliance
- Uni-directional through serial port interface
- 15 to 30°C (65 to 85°F) Room temperature, 20 to 80% humidity
- Microprocessor-verified between 18,000 and 22,000 rpm centrifuge speed
- Dendrimer enhanced radial partition immunoassay
- The last 20 results are stored and can be reprinted or transmitted to LIS
- Patient ID and/or sample ID entry sample collection time entry
- Unauthorized operator lockout capability
- TestPak lot expiration notification
- Password protection of advanced setup functions
Professionals Also Viewed
- #1168284
- Beckman Coulter #A11200
- Refurbished Access 2 Analyzer
- The Access 2 was designed to have the robustness of a reference-lab im …
- The Access 2 delivers an extensive immunoassay diagnostic-testing menu …
- #1072554
- Qualigen #853988-R
- One touch operation
- All inclusive reagent pack
- Lab quality precision
- #989185
- 昊图公司临床Diagnostics #6802914
- Measurement principle: Enhanced chemiluminescence using MicroWell tech …
- Calibration: 25 lots per assay may be calibrated with automatic lot; s …
- Sample containers: Universal sample trays accommodate: 5 mL, 7 mL, 10 …
- #1062045
- 昊图公司临床Diagnostics #6801059
- Measurement principle: Enhanced chemiluminescence
- MicroWell technology: Excellent assay sensitivity and precision, small …
- Calibration: Multiple lots may be pre-calibrated with automatic lot sw …
Related Products
没有图像
- # 1033820
- Siemens #10445064
没有图像
- # 1033821
- Siemens #10445066
- The Stratus® CS Acute Care™ CardioPhase® High Sensitivity C-reactive P …
- The Acute Care™ CardioPhase® CCRP CalPak is a single-use product which …
- The Acute Care™ CardioPhase® CCRP CalPak contains native CRP in a huma …
没有图像
- #1033822
- Siemens #10445067
- WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
没有图像
- #1033824
- Siemens #10445077
- The Stratus® CS Acute Care™ D-dimer Dilution Pak (DDMR DilPak), Catalo …
- The Stratus® CS Acute Care™ DDMR DilPak contains a liquid buffered bov …
- WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov